GSM-Forum
RNE-AL00 read code successyfly done
mobile in phone model supported in sigma box but failed :confused::confused::confused:request root HHHHHH
xxxxxxxxxx Sigma dongle 2.28, Initializing...OK
Pack 1: Activated
Pack 2: Activated
Pack 3: Activated
--------- 2018-08-09 18:13:11 ---------
SigmaKey 2.28.07 HiSi: Get Huawei bootloader password
Connecting...Reboot phone and try again
--------- 2018-08-09 18:13:23 ---------
SigmaKey 2.28.07 HiSi: Get Huawei bootloader password
Connecting...Reboot phone and try again
--------- 2018-08-09 18:13:34 ---------
SigmaKey 2.28.07 HiSi: Get Huawei bootloader password
Connecting....
Android Adapter PCUI (COM351), Provider: Huawei Incorporated, Driver ver.: 2.0.6.725, Date: 28/12/2015, USB\Vid_12D1&Subclass_13&Prot_22
Firmware: System 8.0.0.046(0BHN), Date: Wed May 23 12:52:37 CST 2018, Provider: all/cn
Boot Version: System 8.0.0.046(0BHN)_BOOT, FastBoot Version: Chipset-dallas8.0.1.001(010G)_FASTBOOT
Recovery Version: (unknow), System Version: System 8.0.0.046(0BHN)
Removing firmware protection...Unable to connect to the server. Please check your network.
Removing firmware protection...^ Android Composite ADB Interface
Preparing...Please ROOT the phone first!
--------- 2018-08-09 18:15:51 ---------
SigmaKey 2.28.07 HiSi: Get Huawei bootloader password
Connecting....
Android Adapter PCUI (COM351), Provider: Huawei Incorporated, Driver ver.: 2.0.6.725, Date: 28/12/2015, USB\Vid_12D1&Subclass_13&Prot_22
Firmware: System 8.0.0.046(0BHN), Date: Wed May 23 12:52:37 CST 2018, Provider: all/cn
Boot Version: System 8.0.0.046(0BHN)_BOOT, FastBoot Version: Chipset-dallas8.0.1.001(010G)_FASTBOOT
Recovery Version: (unknow), System Version: System 8.0.0.046(0BHN)
Removing firmware protection...Unable to connect to the server. Please check your network.
Removing firmware protection...^ Android Composite ADB Interface
Unexpected response from the phonein Octopus Huawei Software v.1.0.3 model not in supported list but OK in 3 second
2018-08-09 17:17:44.558
2018-08-09 17:17:44.559 To enable 'Manufacture' mode dial
2018-08-09 17:17:44.560 - for Qualcomm and Hisilicon based models: *#*#2846579#*#*
2018-08-09 17:17:44.562 ProjectMenu > Background Settings > USB Port Settings > Manufacture Mode
2018-08-09 17:17:44.563
2018-08-09 17:17:44.563 To enable 'Fastboot' mode
2018-08-09 17:17:44.565 1. Power off the phone. Remove SD and SIM cards
2018-08-09 17:17:44.566 2. Press 'Vol-' and insert USB cable
2018-08-09 17:17:44.566 3. Wait until phone enters 'Fastboot' mode
2018-08-09 17:17:44.585 Refreshing serial ports list
2018-08-09 17:17:45.023 Found COM ports:
2018-08-09 17:17:45.024 1: COM3 USB Serial Port
2018-08-09 17:17:45.024 2: COM352 HUAWEI Mobile Connect - Fake Acm Interface
2018-08-09 17:17:45.024 3: COM21 USB Serial Port
2018-08-09 17:17:45.025 4: COM350 HUAWEI Mobile Connect - Fake Acm Interface
2018-08-09 17:17:45.025 5: COM351 Android Adapter PCUI
2018-08-09 17:17:45.025 6: COM353 DBAdapter Reserved Interface
2018-08-09 17:17:45.025 7: COM1 Port de communication
2018-08-09 17:17:45.026 Loading application settings
2018-08-09 17:17:45.027 Init finished
2018-08-09 17:17:47.741 Refreshing serial ports list
2018-08-09 17:17:48.092 Found COM ports:
2018-08-09 17:17:48.093 1: COM3 USB Serial Port
2018-08-09 17:17:48.094 2: COM352 HUAWEI Mobile Connect - Fake Acm Interface
2018-08-09 17:17:48.094 3: COM21 USB Serial Port
2018-08-09 17:17:48.095 4: COM350 HUAWEI Mobile Connect - Fake Acm Interface
2018-08-09 17:17:48.096 5: COM351 Android Adapter PCUI
2018-08-09 17:17:48.096 6: COM353 DBAdapter Reserved Interface
2018-08-09 17:17:48.097 7: COM1 Port de communication
2018-08-09 17:17:48.097 2018-08-09 17:17:48 GMT -------------------------------------------------
2018-08-09 17:17:48.098 Starting Auto detect
2018-08-09 17:17:48.101 Running detect for HiSilicon
2018-08-09 17:17:48.208 Detect HiSilicon platform ok
2018-08-09 17:17:48.209 Detected HiSilicon Android Device at COM351
2018-08-09 17:17:48.209 Read pre auth info for HiSilicon
2018-08-09 17:17:48.315 Warning: Can't get device model.
2018-08-09 17:17:48.475 Warning: Can't get IMEI/MAC info.
2018-08-09 17:17:48.475 Removing security protection...
2018-08-09 17:17:50.585 Auth 1 HiSilicon fail
2018-08-09 17:17:50.695 Connecting to server...
2018-08-09 17:17:51.880 Check auth 3
2018-08-09 17:17:52.952 Authorization successful
2018-08-09 17:17:52.952 Reading basic data...
2018-08-09 17:17:53.457 Reading secure data...
2018-08-09 17:18:00.051 Device Model: RNE-AL00
2018-08-09 17:18:00.053 Firmware: System 8.0.0.046(0BHN)
2018-08-09 17:18:00.053 Boot: System 8.0.0.046(0BHN)_BOOT
2018-08-09 17:18:00.054 Fastboot: Chipset-dallas8.0.1.001(010G)_FASTBOOT
2018-08-09 17:18:00.055 System: System 8.0.0.046(0BHN)
2018-08-09 17:18:00.055 Recovery: (unknow)
2018-08-09 17:18:00.056 MEID: A0000082235AF8
2018-08-09 17:18:00.057 PESN: 80811DDB
2018-08-09 17:18:00.057 IMEI A: 867540036319538
2018-08-09 17:18:00.058 IMEI B: 867540036411947
2018-08-09 17:18:00.058 Bluetooth MAC: 10:44:00:74:A7:21
2018-08-09 17:18:00.059 WiFi MAC: 10:44:00:74:CC:ED
2018-08-09 17:18:00.059 S/N: 68UDU17B17001361
2018-08-09 17:18:00.060 Board S/N: DU4MJA17BK103461
2018-08-09 17:18:00.060 Vendor Code: all
2018-08-09 17:18:00.061 Country Code: cn
2018-08-09 17:18:00.061
2018-08-09 17:18:00.062 Auto detect done.
2018-08-09 17:18:00.063 Performed by 1.0.3 Software version.
2018-08-09 17:18:03.192 2018-08-09 17:18:03 GMT -------------------------------------------------
2018-08-09 17:18:03.193 Starting Read Bootloader Code
2018-08-09 17:18:03.194 Reading basic data...
2018-08-09 17:18:03.708 Reading secure data...
2018-08-09 17:18:10.414 Bootloader code: 8548708005626027
2018-08-09 17:18:10.415
2018-08-09 17:18:10.415 Read Bootloader Code done.
2018-08-09 17:18:10.416 Performed by 1.0.3 Software version.after great work and bootloader unlocked successufly and rooted 100 %
Code:
SigmaKey v.2.28.07xxxxxxxxxx Sigma dongle 2.28, Initializing...OK
Pack 1: Activated
Pack 2: Activated
Pack 3: Activated
--------- 2018-08-09 18:13:11 ---------
SigmaKey 2.28.07 HiSi: Get Huawei bootloader password
Connecting...Reboot phone and try again
--------- 2018-08-09 18:13:23 ---------
SigmaKey 2.28.07 HiSi: Get Huawei bootloader password
Connecting...Reboot phone and try again
--------- 2018-08-09 18:13:34 ---------
SigmaKey 2.28.07 HiSi: Get Huawei bootloader password
Connecting....
Android Adapter PCUI (COM351), Provider: Huawei Incorporated, Driver ver.: 2.0.6.725, Date: 28/12/2015, USB\Vid_12D1&Subclass_13&Prot_22
Firmware: System 8.0.0.046(0BHN), Date: Wed May 23 12:52:37 CST 2018, Provider: all/cn
Boot Version: System 8.0.0.046(0BHN)_BOOT, FastBoot Version: Chipset-dallas8.0.1.001(010G)_FASTBOOT
Recovery Version: (unknow), System Version: System 8.0.0.046(0BHN)
Removing firmware protection...Unable to connect to the server. Please check your network.
Removing firmware protection...^ Android Composite ADB Interface
Preparing...Please ROOT the phone first!
--------- 2018-08-09 18:15:51 ---------
SigmaKey 2.28.07 HiSi: Get Huawei bootloader password
Connecting....
Android Adapter PCUI (COM351), Provider: Huawei Incorporated, Driver ver.: 2.0.6.725, Date: 28/12/2015, USB\Vid_12D1&Subclass_13&Prot_22
Firmware: System 8.0.0.046(0BHN), Date: Wed May 23 12:52:37 CST 2018, Provider: all/cn
Boot Version: System 8.0.0.046(0BHN)_BOOT, FastBoot Version: Chipset-dallas8.0.1.001(010G)_FASTBOOT
Recovery Version: (unknow), System Version: System 8.0.0.046(0BHN)
Removing firmware protection...Unable to connect to the server. Please check your network.
Removing firmware protection...^ Android Composite ADB Interface
Unexpected response from the phone
Code:
2018-08-09 17:17:44.557 Welcome to Octoplus/Octopus Huawei Software v.1.0.32018-08-09 17:17:44.558
2018-08-09 17:17:44.559 To enable 'Manufacture' mode dial
2018-08-09 17:17:44.560 - for Qualcomm and Hisilicon based models: *#*#2846579#*#*
2018-08-09 17:17:44.562 ProjectMenu > Background Settings > USB Port Settings > Manufacture Mode
2018-08-09 17:17:44.563
2018-08-09 17:17:44.563 To enable 'Fastboot' mode
2018-08-09 17:17:44.565 1. Power off the phone. Remove SD and SIM cards
2018-08-09 17:17:44.566 2. Press 'Vol-' and insert USB cable
2018-08-09 17:17:44.566 3. Wait until phone enters 'Fastboot' mode
2018-08-09 17:17:44.585 Refreshing serial ports list
2018-08-09 17:17:45.023 Found COM ports:
2018-08-09 17:17:45.024 1: COM3 USB Serial Port
2018-08-09 17:17:45.024 2: COM352 HUAWEI Mobile Connect - Fake Acm Interface
2018-08-09 17:17:45.024 3: COM21 USB Serial Port
2018-08-09 17:17:45.025 4: COM350 HUAWEI Mobile Connect - Fake Acm Interface
2018-08-09 17:17:45.025 5: COM351 Android Adapter PCUI
2018-08-09 17:17:45.025 6: COM353 DBAdapter Reserved Interface
2018-08-09 17:17:45.025 7: COM1 Port de communication
2018-08-09 17:17:45.026 Loading application settings
2018-08-09 17:17:45.027 Init finished
2018-08-09 17:17:47.741 Refreshing serial ports list
2018-08-09 17:17:48.092 Found COM ports:
2018-08-09 17:17:48.093 1: COM3 USB Serial Port
2018-08-09 17:17:48.094 2: COM352 HUAWEI Mobile Connect - Fake Acm Interface
2018-08-09 17:17:48.094 3: COM21 USB Serial Port
2018-08-09 17:17:48.095 4: COM350 HUAWEI Mobile Connect - Fake Acm Interface
2018-08-09 17:17:48.096 5: COM351 Android Adapter PCUI
2018-08-09 17:17:48.096 6: COM353 DBAdapter Reserved Interface
2018-08-09 17:17:48.097 7: COM1 Port de communication
2018-08-09 17:17:48.097 2018-08-09 17:17:48 GMT -------------------------------------------------
2018-08-09 17:17:48.098 Starting Auto detect
2018-08-09 17:17:48.101 Running detect for HiSilicon
2018-08-09 17:17:48.208 Detect HiSilicon platform ok
2018-08-09 17:17:48.209 Detected HiSilicon Android Device at COM351
2018-08-09 17:17:48.209 Read pre auth info for HiSilicon
2018-08-09 17:17:48.315 Warning: Can't get device model.
2018-08-09 17:17:48.475 Warning: Can't get IMEI/MAC info.
2018-08-09 17:17:48.475 Removing security protection...
2018-08-09 17:17:50.585 Auth 1 HiSilicon fail
2018-08-09 17:17:50.695 Connecting to server...
2018-08-09 17:17:51.880 Check auth 3
2018-08-09 17:17:52.952 Authorization successful
2018-08-09 17:17:52.952 Reading basic data...
2018-08-09 17:17:53.457 Reading secure data...
2018-08-09 17:18:00.051 Device Model: RNE-AL00
2018-08-09 17:18:00.053 Firmware: System 8.0.0.046(0BHN)
2018-08-09 17:18:00.053 Boot: System 8.0.0.046(0BHN)_BOOT
2018-08-09 17:18:00.054 Fastboot: Chipset-dallas8.0.1.001(010G)_FASTBOOT
2018-08-09 17:18:00.055 System: System 8.0.0.046(0BHN)
2018-08-09 17:18:00.055 Recovery: (unknow)
2018-08-09 17:18:00.056 MEID: A0000082235AF8
2018-08-09 17:18:00.057 PESN: 80811DDB
2018-08-09 17:18:00.057 IMEI A: 867540036319538
2018-08-09 17:18:00.058 IMEI B: 867540036411947
2018-08-09 17:18:00.058 Bluetooth MAC: 10:44:00:74:A7:21
2018-08-09 17:18:00.059 WiFi MAC: 10:44:00:74:CC:ED
2018-08-09 17:18:00.059 S/N: 68UDU17B17001361
2018-08-09 17:18:00.060 Board S/N: DU4MJA17BK103461
2018-08-09 17:18:00.060 Vendor Code: all
2018-08-09 17:18:00.061 Country Code: cn
2018-08-09 17:18:00.061
2018-08-09 17:18:00.062 Auto detect done.
2018-08-09 17:18:00.063 Performed by 1.0.3 Software version.
2018-08-09 17:18:03.192 2018-08-09 17:18:03 GMT -------------------------------------------------
2018-08-09 17:18:03.193 Starting Read Bootloader Code
2018-08-09 17:18:03.194 Reading basic data...
2018-08-09 17:18:03.708 Reading secure data...
2018-08-09 17:18:10.414 Bootloader code: 8548708005626027
2018-08-09 17:18:10.415
2018-08-09 17:18:10.415 Read Bootloader Code done.
2018-08-09 17:18:10.416 Performed by 1.0.3 Software version.
Aucun commentaire:
Enregistrer un commentaire